Skip to main content

Calibrating thermometers

  • Print this page
  • Download as PDF
  • Share this page

All food businesses that handle potentially hazardous food are required to have at least one thermometer accurate to +/-1°C readily accessible at all times.  

 The thermometer needs to be available for use when foods are being prepared, stored, transported or displayed, so you may need more than one if foods are handled in different places.

Thermometers must be calibrated regularly to ensure accuracy. Calibration is recommended at least once every 6 months, depending on use.  

How thermometers are calibrated is a decision for the business. However, using both the ice point and boiling point methods outlined below will ensure accuracy in the thermometer’s upper and lower ranges.

Records of calibration should always be maintained. If using an external contractor, calibration records should include date, serial number, correction factor, and location and type of equipment.

Ice point calibration

  1. Place some ice into a container with a small amount of cold water. The ice should not float if the right amount of water is used.
  2. Mix into a slurry and insert the thermometer probe.
  3. Leave it for about 3 minutes.
  4. Check and note the temperature. It should read 0°C.
  5. Do this 3 times and compare the temperatures recorded. If they vary by more than 1°C, the thermometer should be replaced or serviced.

Boiling point calibration

  1. Bring a saucepan of water to a continuous rolling boil on a stove.
  2. Insert the thermometer probe and leave it for about 3 minutes.
  3. Check and note the temperature. It should read 100°C (unless in an area of high altitude – see ‘Calibration in varied altitudes’ below).
  4. Do this 3 times and compare the temperatures recorded. If they vary by more than 1°C, the thermometer should be replaced or serviced.

Mechanical calibration

Some thermometers may come with a mechanical calibration unit. If so, follow the manufacturer’s directions on calibrating your thermometer. You may also be able to return your thermometer to the manufacturer. 

Calibration in varied altitudes

Australian mountain ranges do not have sufficient height to cause the problems in cooking seen on Everest or in Colorado due to reduced boiling points but they are high enough to interfere with thermometer calibration.

Water will boil at temperatures around 94°C at the highest towns in NSW, so if the expectation is 100°C, thermometers appear to exceed the +/- 1°C tolerance.  

Those calibrating thermometers and undertaking internal and external audits should note the reduced boiling point of water at higher altitude towns in the table below.

Table 1: Approximate boiling point of water for higher towns in NSW. 

TownElevationBP C
Perisher Village172194.2
Cabramurra146194.9
Thredbo Village144795.2
Guyra133695.5
Oberon110396.3
Nimmitabel108296.3
Mount Victoria107196.3
Glen Innes107196.3
Blackheath106796.3
Medlow Bath106496.5
Walcha104796.5
Adaminaby102696.5
Katoomba102596.5
Uralla100496.5
Armidale98296.8
Lakewood Estate97096.8
Millthorpe96996.8
Deepwater96796.8
Spring Hill94796.8
Portland94496.8
Jindabyne91896.8
Lithgow91696.8
Wallerawang89897.1
Crookwell89697.1
Emmaville88697.1
Cullen Bullen87997.1
Blayney87497.1
Wentworth Falls87197.1
Orange86997.1
Berridale86297.1
Clifton Grove85597.1
Tenterfield85197.1
Captains Flat84897.1
Taralga84297.1
Bendemeer82697.3
Cooma79397.3
Tingha78697.3
Batlow78097.3
Delegate76197.6
Dorrigo75597.6
Gilgai74197.6
Robertson73197.6
Lawson72897.6
Exeter71297.6
Bombala70197.6
Bungendore69597.6
Wingello68597.8
Bowral68197.8
Moss Vale67897.8
Perthville67897.8

 

Table 2: Boiling point of water at varying altitudes

Altitude (m above sea level)Boiling Point °C
0100.0
7699.7
15299.5
22999.2
30598.9
38198.6
45798.4
53398.1
61097.8
68697.6
76297.3
83897.1
91496.8
99196.5
106796.3
114396.0
121995.7
129595.5
137295.2
144894.9
152494.7
160094.4
167694.2
175393.9

 

Coolroom/freezer gauges calibration

Once the handheld thermometer is calibrated it can also be used to check the accuracy of any temperature gauges on equipment, such as coolrooms and freezers. This should be done at least 6 monthly.  

  • Place the thermometer in the coolroom/freezer, with the thermometer probe placed as close to the gauge probe as possible, for at least 5 minutes (making sure not to open the door during this period).
  • After this period, read the temperature on the thermometer (taking into account any difference noted during the calibration of the handheld thermometer).
  • Read the temperature on the gauge and determine any difference between the handheld thermometer reading and the gauge, as above.
  • Be sure to clean and sanitise the thermometer before taking the temperature of food. 

How to clean and use a probe thermometer

Prior to taking the temperature of food, thermometer probes must be cleaned, and then sanitised.

  • Clean off any food waste or other visible contamination.
  • Wash and dry the probe with warm water and detergent.
  • Sanitise using an appropriate food grade sanitiser (for example, an alcohol wipe) or water 77°C or hotter for at least 30 seconds. Follow the manufacturer's instructions.
  • Air dry or use a single-use towel.
  • Insert the probe into the centre or thickest part of the food. For packaged products, place the probe between two packages.
  • Read the temperature (and record it if applicable).

Always remember to:

  • put the probe into the thickest part or the centre of the food  
  • wash and sanitise the probe between every reading
  • store the probe where all staff can access it
  • make sure the thermometer is calibrated regularly
  • fix the problem if food is not at the required temperature, for example, continue to heat it or throw it out. 
Was this page helpful?